MIL-PRF-11264F
TABLE I. Classification of defects.
Method of
Category
Defect
examination
Critical
1
Lifting device warning markings omitted (see
Visual
3.3.8.3.1.1 and 3.3.8.4.1.2).
2
Container type not as specified (see 1.2).
Visual
Major:
101
Identification marking improper (see 3.3.8).
Visual
102
Ventilation holes missing (see 3.3.2.5).
Visual
103
Cradles or axle supports missing where applicable
Visual and
(see 3.3.2.7 through 3.3.2.9).
Functional
104
Openings not protected against infestation (see
Visual
3.3.2.10).
Minor:
201
Inspection hinges missing (see 3.3.2.3).
Visual
202
Cover or base not interchangeable with like unit of Functional
same type and design container (see 3.3.9).
203
Workmanship faulty (see 3.3.7).
Visual
TABLE II. Classification of tests.
Conformance
First Acceptance
article
(100%)
Control
Title
Requirement
Test
X
Stackability
3.3.1.1
4.6.2.1
X
X
Rough handling
Cornerwise-drop
3.3.1.2.1
4.6.2.2.1
X
X
X
Pendulum-impact
3.3.1.2.2
4.6.2.2.2
X
X
X
Incline-impact
3.3.1.2.3
4.6.2.2.3
X
X
X
Edgewise-drop
3.3.1.2.4
4.6.2.2.4
X
X
X
Vibration
3.3.1.2.5
4.6.2.2.5
X
X
X
Drainage
3.3.2.4
4.6.3.2
X
Water resistance
3.3.2.6
4.6.3.4
X
X
X
Interface characteristics
3.3.3
4.6.4
X
Cover-lifting devices
3.3.3.1
4.6.4.1
X
X
X
Environmental
conditions
Temperature
3.3.6.1
4.6.5.1
X
Humidity
3.3.6.2
4.6.5.2
X
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.